Sentinel Alarm Setup Display

Alarms are the result of one or more error conditions. Four alarms are available and each may have any combination of errors assigned to it. These result in actions based on settings in the ALARM ACTION panel.

The ALARM SETUP panel has 4 columns, each corresponding to one of the 4 alarms. Each row of the panel corresponds to one type of detected error. Checking the box at the intersection of an error row with an alarm column enables that type of error to cause the numbered alarm. The Sentinel front panel ALARM indicator displays this numeric error code.

  1. Under Level enables reporting of under-level errors.

  2. Over Level enables reporting of levels exceeding the specified operating level.

  3. Clipping enables reporting of channel clipping.

  4. Hum enables reporting mains hum errors.

  5. Channel Swap enables reporting of interchanged channels.

  6. Program Loudness enables reporting of program loudness being out of bounds.

  7. Downmix Compatibility enables reporting stereo and mono downmix compatibility errors.

  8. LFE Bandwidth enables reporting of excessive LFE bandwidth.

  9. Input Connections enables reporting of digital input link errors.

  10. Group Consistency enables reporting of cross channel format inconsistencies.

  11. Input Metadata enables reporting of individual channel metadata errors.

  12. Group Metadata enables reporting of cross channel metadata inconsistencies.

  13. Dialnorm enables reporting when the dialnorm value measured on the program differs from the dialnorm value coded in the metadata.

  14. AC3 Packets enables reporting of packet coding errors.

  15. AC3 Metadata enables reporting of errors in the coded audio metadata.

  16. DC Input # enables reporting of that DC input being out of bounds.

  17. Temperature enables reporting of temperature errors.